892 Mountain View Drive

Park City, UT 00000
Inspected on March 18, 2026
Prepared by Olympus Home Inspections

For Consideration

23

Missing Fastener

Moderate
The dishwasher is not completely fastened. Recommend fastening the dishwasher as needed.
photo_1773848474403.jpg

Igniter Continues Clicking

Moderate
The burner igniter is staying on after the burner lights on the front left burner. Recommend an appliance contractor evaluates and repairs as needed.
133FD88E-9886-4ECE-868D-A19BBCD60BE2.heic

Poor/Missing Caulk

Moderate
A countertop was missing sufficient caulk/sealant at the wall. This can lead to water damage. Recommend adding sealant at sides and corners where counters touch walls.
photo_1773853596925.jpg
photo_1773853606265.jpg
photo_1773853601480.jpg

Carpet Stains

Moderate
Carpet had areas of staining or discoloration. Recommend a thorough steam clean by a qualified carpet cleaning company.
photo_1773850282535.jpg

Light Inoperable

Moderate
One or more lights were observed to not function at the time of inspection. Bulb Replacement is likely needed.
photo_1773850643417.jpg
photo_1773850677525.jpg
54A75150-0276-4B3C-98CA-E3D56B1EBB27.jpeg

Deck - Paint/Stain Maintenance Required

Moderate
Deck is showing signs of weathering and/or water damage. Recommend water sealant/weatherproofing be applied. Here is a helpful article on staining & sealing your deck.
photo_1773846536263.jpg
photo_1773846617537.jpg

Stain Faded/Worn

Moderate
The stain on the exterior walls is worn and faded in some areas. Recommend re-staining as needed.
photo_1773846556272.jpg
photo_1773846169809.jpg

Evidence of Pest Activity

Moderate
There is evidence of pest activity around the home. Recommend consulting with a pest control company.
photo_1773846416520.jpg

Paint/Refinish Needed

Moderate
Door finish is worn. Recommend refinish and/or paint to maximize service life.
photo_1773846263277.jpg
photo_1773846259824.jpg
photo_1773846251024.jpg

Driveway Spalling

Moderate
Areas of the driveway have spalling. Recommend sealing the concrete and monitoring or consulting with a concrete or concrete coating contractor.
photo_1773846044705.jpg

Deck - Handrail Loose

Moderate
The deck handrail was observed to be loose. Recommend a handyman or carpenter secures the handrail.
photo_1773846598932.jpg

Fireplace did not light

Moderate
The fireplace was observed to not light using the operating controls. Recommend a qualified contractor evaluates and repairs the fireplace as needed.
4E320EEF-FE27-4E02-A4C2-2A1261291D97.heic
1187883F-6099-4A08-9CDB-9DA9B29018BD.heic

Vent Hanging Down

Moderate
One of the ceiling mounted vents is hanging down. Recommend re-fastening the vent to the ceiling.
photo_1773850151110.jpg

Sewer Gas Smell

Moderate
A sewer gas odor was present in the primary bathroom. Recommend a plumber evaluates. There might be a seal on a drain fitting that is not fully sealed.
photo_1773849255958.jpg

Downspouts Drain Near House

Moderate
One or more downspouts drain too close to the home's foundation. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a qual...
photo_1773845999899.jpg
photo_1773845978887.jpg
photo_1773846327864.jpg
photo_1773846330362.jpg
photo_1773846463663.jpg

Moderate Wear

Minor
Floors in the home exhibited moderate surface wear along major paths of travel. Recommend a qualified flooring contractor evaluate for possible re-finish.
photo_1773849755904.jpg

Driveway Cracking

Minor
Cracking was observed on the driveway. Recommend monitoring for movement and sealing cracks to prevent water from entering them.
photo_1773846295647.jpg

Chimney Liner Dirty

Minor
Chimney liner had layer of creosote dust. Recommend qualified chimney sweep company inspect and/or clean the chimney prior to use.
6554E528-3641-49ED-8A3C-E1E9770B2884.heic

HVAC Filter Dirty

Minor
The furnace filter is dirty and needs to be replaced . Recommend replacing the filter at least every 6 months, or more often if it is dirty sooner.
56D04439-7947-4A11-8B6B-15B68C833547.heic

Shower Valve Missing Stops

Minor
A shower valve was observed to be missing the stops meaning the off position does not have a positive stop or marker to turn off the shower and the valve handle can be spun 360 degrees.
photo_1773849441115.jpg
photo_1773851645973.jpg

Sink - Poor Drainage

Minor
Sink had slow/poor drainage. Recommend a qualified plumber repair.
3C776267-69DC-4737-9767-5C1609E79530.heic
7FC3C7F6-5DD7-4351-B627-715C36871AE7.heic

Shower Head Leaking at Gooseneck

Minor
The shower head was observed leaking at the connection between the gooseneck extending from the wall and the shower head.
photo_1773849465258.jpg

Loose Tub Filler

Minor
One or more tub filler spouts were observed to be loosely mounted. Recommend a plumber tightens as needed.
photo_1773849310767.jpg

Limitations

1

Turned Off

The refrigerator has power but was turned off at the time of inspection. Recommend turning on the refrigerator and testing.
51FE736E-16A8-43AD-A2E7-5672903770E1.jpeg
32D81D27-E65F-47EC-82F7-6F5B1CE92672.heic