1234 Sample Street

Anytown, UT 00000
Inspected on May 18, 2026
Prepared by Olympus Home Inspections

For Consideration

27

Smoke Detectors Missing in Required Location

Safety
One or more areas that should contain a smoke detector did not have a detector present. It is recommended that smoke detectors be located in bedrooms, outside of sleeping areas, and on every level of ...

Cracked Glass

Major
One or more windows were observed with broken glass. Recommend replacing the window or the broken glass.
BAAAF0E7-0484-4A99-976C-C4B14A69676E.jpg
5DE0816A-40D5-4C34-A4DB-5361128506C6.jpg
88B9BDE4-968C-447D-A6C0-28BFCBB08A6C.jpg

Exterior Sealant Incomplete

Major
One or more windows were observed to have incomplete or missing exterior sealant. Recommend resealing the window.
145FFB0F-3723-4D60-9B20-431D87611802.jpg
AEBE47BB-D50A-4FA0-ABC4-42BC82EFDFBA.jpg
65826BAD-05D0-4714-9344-BD0127E99303.jpg

Evidence of Water Intrusion

Major
The basement windows have evidence of water having coming past the window. Recommend resealing and digging out window wells as needed.
27380520-3B04-4C3F-8036-ECF8F3B13370.jpg
05E4EAE5-A1EE-4C3C-80E3-65BB3368356A.jpg
96AD33B8-E14A-475D-9FE2-3935D4C93E3C.jpg

Incomplete Ceiling

Major
The garage ceiling is incomplete and does not function as a fire break or to prevent gasses from entering the attic. Recommend patching drywall and installing an attic hatch as needed.
466CBF1A-FB9A-4087-802A-89BE6A383C3F.jpg
5FE693D6-ADBF-4011-B27A-E6183AA0184F.jpg

No Earthquake Straps

Major
It is recommended that water heaters be secured by straps or a bracket to prevent them from tipping over in the event of an earthquake or similar event. Recommend adding a strap or bracket to the wate...
B9D3B014-687D-4273-A350-51B3C05373BE.jpg

Roof Leaking

Major
There is a wet area and some other staining on the roof deck near the chimney. Recommend a roofer evaluates the roof in this area and repairs the flashing at the chimney. Large amounts of sealant were...
3B330266-035D-4F39-B030-2EE1BD5A4B7B.jpg
C60A4C16-EF8B-43B0-8CE9-AC212516EFE4.jpg
1D6A2CD6-7132-48CA-835B-BC75A25176CB.jpg
01CD9AC2-D32A-44A9-9143-07DAD20DEBB3.jpg
31C24835-6C8A-4625-A799-2DEB591E1412.jpg

Uneven Carpet

Moderate
The carpets were observed to be loose in some areas or to have raised seams. Recommend a carpet contractor repairs as needed.
9216F6A5-67CE-43F3-83AB-0D7B94C9F34C.jpg
7B0EAE20-751C-4D0E-B84A-A316327F373F.jpg

Countertop Damaged

Moderate
Countertops had areas where the laminate top is not well adhered to the base. Recommend adhering the countertops to the base as needed.
A8AB83E3-997F-4BC8-9374-DCCDE43AF744.jpg

Damaged (General)

Moderate
The floors in the home had general moderate damage visible at the time of the inspection. Recommend service by a qualified contractor.
B409904E-5834-4211-A9C6-41124707C658.jpg
20560277-6609-403A-8950-85DB6473C641.jpg

Minor Damage/Patches

Moderate
Walls had minor damage and patches needed at the time of inspection. Recommend a handyman or drywall contractor repairs the walls.
F47F2448-36D8-4E19-8A17-DD9578341038.jpg
B6178BD9-D723-4243-A063-61B8C3059B9E.jpg

Exterior Outlet Not GFCI Protected

Moderate
One or more exterior outlets were observed to not be GFCI protected. Recommend an electrician evaluates the outlets and installs GFCI protection.
328881C6-EEB2-4937-B2BB-A7162942E3A7.jpg

Garage Outlets Not GFCI Protected

Moderate
One or more garage outlets were observed to not be GFCI protected. Recommend an electrician evaluates the garage outlets and installs GFCI protection.
CB6B1FAC-FB09-451B-B0AF-30CB36AC9DD6.jpg

Kitchen Outlet Not GFCI Protected

Moderate
One or more kitchen outlets were observed to not have GFCI protection. Recommend an electrician evaluates the outlets and updates them to have GFCI protection.
B5929722-F423-4086-9355-CB0431C1B396.jpg
350F34A4-F257-44DC-9E9F-C107C6EB7E30.jpg

Unsealed Opening

Moderate
There is an unsealed opening in the exterior of the home. Recommend sealing this opening.
7F385BF0-0B8E-4BF0-8A6F-5A38EEA601FF.jpg

Loose Boards

Moderate
One or more siding boards were loose, which could result in moisture intrusion. Recommend a qualified siding contractor secure and fasten.
47FA0BC2-B164-45CA-B001-6ADF66CFA720.jpg
23F17D2B-E530-408E-AD4C-0AB3086C9A2B.jpg

Concrete Cracking

Moderate
Cracking was observed in the concrete. Recommend grinding down cracks that pose trip hazards and sealing cracks or replacing the concrete as needed to eliminate cracks.
DBB52E3E-1469-4FE2-96F3-01BB06986E42.jpg
17B0D30A-2BBE-4975-8C9D-13EF83486F0E.jpg

Driveway Cracking

Moderate
Cracking was observed on the driveway. Recommend monitoring for movement and sealing cracks to prevent water from entering them.
4C54C5C8-A790-409E-9B81-2FC29D568538.jpg

Door Stuck Shut

Moderate
The right side door of the basement fireplace requires excessive force to open. Recommend repairing as needed.
A99AB6E8-8546-4AD2-8182-38296C9FEAE9.jpg

Foundation Cracks - Minor

Moderate
Minor cracking was noted at the foundation. This is common as concrete ages and shrinkage surface cracks are normal. Recommend monitoring for more serious shifting/displacement.  Here is an informati...
A9BF151E-B561-4B85-9BE6-8C49D83A6635.jpg

Filter Dirty

Moderate
The furnace filter is dirty and needs to be replaced every 6 months.
F87D87C6-BF67-41C3-8CAA-86EF553D1F43.jpg

Gutter Leakage

Moderate
Gutters were observed to be leaking in one or more areas. This can result in water damage to areas below. Recommend a qualified contractor evaluate and repair gutters to proper functionality.
68DC8444-9D7A-4700-9087-34796DCF59F1.jpg

Downspouts Drain Near House

Moderate
One or more downspouts drain too close to the home's foundation. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a qual...
D860FBE2-726F-4BA4-A767-B00E6D41D128.jpg
8A82BC96-3AC0-4937-B2B7-B9212FF9D575.jpg
870682E7-19E2-40EF-9797-22C7214557E8.jpg

Door Rubs On Flooring

Minor
One or more doors were observed to be rubbing on the flooring. Recommend adjusting the door or trimming the door to prevent flooring damage.
1746A46C-0DAB-4575-AC59-E6E3B3EB8C1C.jpg

Cover Plates Missing

Minor
One or more receptacles are missing a cover plate. This causes short and shock risk. Recommend installation of plates.
BF0B1E23-2D1B-4A51-9B28-159B254BA15F.jpg

Light Inoperable

Minor
One or more lights were observed to not function at the time of inspection. Bulb Replacement is likely needed.
42838E84-F9D3-41EC-9CBB-A063F2D63400.jpg
3E31F54B-56DE-49DD-A3AF-BEFE5B14D1E8.jpg
7F8FE4CD-EE56-437C-A863-93D4BA353DC3.jpg

Paint/Refinish Needed

Minor
Door finish is worn. Recommend refinish and/or paint to maximize service life. Here is a DIY article on refinishing a wood door.
1347E004-03CA-4533-B1B1-26014C6DFB29.jpg
8DE687B0-BBA7-48CA-B555-6096ADDABB55.jpg

Limitations

2

Low Temperature

The A/C unit was not tested due to low outdoor temperature below 50 degrees. This may cause damage to the unit.

Firebox Blocked Off

The basement firebox has a liner in it blocking the areas off. Recommend a fireplace contractor removes any blocking material and evaluates the unit prior to used.
30D69FA5-8645-4D3A-BFB5-901802764018.jpg
F2741765-B963-438E-BAF1-DA204D8C61D4.jpg

Sample inspection by Olympus Home Inspections on Hometrace