20

Siding Cracking

Major
Siding showed cracking in one or more places. Recommend a siding contractor evaluates as needed.
photo_1770673796665.jpg
photo_1770673798111.jpg

Wall Cracking

Moderate
Vertical cracking visible in painted interior wall near a window/trim. Recommend patching and monitoring; if cracks reappear or widen, consult a qualified contractor to evaluate underlying movement or...
IMG_2026-01-23_09-09-19_683.jpg

Countertop Scratched

Moderate
There are surface scratches and wear on the kitchen countertop. Recommend having a countertop contractor evaluate for possible refinishing or repair.

Damaged / missing floor transition at bathroom threshold

Moderate
Transition strip at threshold between plank-style flooring and ceramic tile is missing/uneven and shows a damaged condition. Recommend installing or replacing the transition strip and securing edges t...
IMG_3081.HEIC
IMG_3086.HEIC

Frayed/deteriorated wiring sheathing observed in panel

Moderate
Wires on service entrance are damaged or frayed. Recommend contacting your electric utility company or a qualified electrician to evaluate and repair.

Furnace should be cleaned and serviced annually

Moderate
Furnace should be cleaned and serviced annually. Recommend a qualified HVAC contractor clean, service and certify furnace.
IMG_3107.HEIC

Venting/flue installation appears non-standard

Moderate
Venting and flue connections were observed to be installed in a non-standard manner. Recommend a qualified plumber or HVAC contractor evaluate the venting and flue connections to confirm compliance wi...
IMG_3104.HEIC
IMG_3114.HEIC

Improper drain connection at sink P-trap

Moderate
Improper connection observed at the sink drain. A flexible corrugated trap/adapter and non-standard fittings are present. These components are prone to debris buildup and may contribute to clogs or le...
IMG_3125.HEIC

Damaged or Missing Screen

Minor
Various window insect screens were observed to be torn or damaged. Recommend replacement of damaged screens to restore insect protection and proper function.
IMG_2026-01-23_09-08-35_554.jpg
IMG_2026-01-23_09-14-37_143.jpg

Damaged Window Sill

Minor
One or more window sills were observed to have damage. Recommend repairing or replacing the damaged sills as needed to maintain integrity and finish.
IMG_3065.HEIC
IMG_3097.HEIC

Minor Damage/Patches

Minor
Minor paint chips, scuffs and corner damage observed. Recommend patching, sanding and repainting as needed to correct the damaged trim and corner areas.
IMG_2026-01-23_09-09-28_826.jpg

Cabinets Damaged

Minor
Cabinets had visible surface damage and paint wear on multiple doors. Recommend a qualified cabinet contractor evaluate and repair as needed.

Wall Damage

Minor
Areas of painted wall have crayon/marker scribbles and surface scuffs. Recommend cleaning, repairing the wall surface as needed, and repainting to restore appearance.
IMG_2026-01-23_09-16-49_991.jpg

Water damaged ceiling

Minor
Water staining and paint bubbling/puckering observed on the bedroom ceiling near a central light fixture. Peeling/separation noted at the ceiling-to-wall joint at one corner. Recommend the source of t...
IMG_2026-01-23_09-17-05_122.jpg
IMG_2026-01-23_09-17-31_429.jpg

Nail pops in ceiling drywall

Minor
Nail or screw heads visible as small bumps or dimples in the ceiling finish. Recommend a drywall contractor recess fasteners, re-tape/skim as needed, and repaint for a finished appearance.
IMG_2026-01-23_09-17-39_380.jpg
IMG_2026-01-23_09-17-43_648.jpg

Flooring surface damage observed

Minor
Delamination and surface damage observed on plank-style resilient flooring in living area/hallway. Temporary duct-tape repairs were noted over damaged planks. Recommend a qualified flooring contractor...
IMG_2026-01-23_09-18-24_890.jpg

Exposed/loose conductors inside panel

Minor
Exposed romex could be seen in some areas. Recommend rerouting in walls or in conduit.
IMG_3122.HEIC

Tub spout not sealed to wall

Minor
The tub spout is not sealed to the wall of the shower. This is a potential leak point and should be sealed to the wall.
IMG_3088.HEIC
IMG_2026-01-23_09-19-11_263.jpg
IMG_2026-01-23_09-20-41_866.jpg

Sink - Poor drainage

Minor
Sink had slow/poor drainage observed (standing water noted in the basin). Recommend a qualified plumber evaluate and repair as needed.
IMG_2026-01-23_09-22-46_342.jpg

Faucet loose/corroded at base

Minor
The bathroom sink faucet was observed to be loose in its mounting and shows corrosion/gap at the base. Recommend a qualified plumber evaluate and tighten or repair the faucet as needed.
IMG_3087.HEIC
IMG_2026-01-23_09-23-09_523.jpg

Limitations

1

Access to water heater partially obstructed

Access to water heater was partially blocked by stored items and shelving in the utility closet. Closed or obstructed access limits ability to perform full service and creates a safety concern. Recomm...
IMG_3101.HEIC
IMG_3116.HEIC