720 Willow Creek Court

Park City, UT 00000
Inspected September 10, 2026Prepared by Evergreen Home Inspections

Overview

18 items

Safety

No Handrail

Staircase had no handrails. This is a safety hazard. Recommend a qualified handyman install a handrail. All stairs with 4 or more risers should have a graspable handrail.
photo_1773777881937.jpg
Major

Siding cracking

Siding showed cracking in one or more places. Recommend a qualified siding contractor evaluate and repair affected sections as needed.
Moderate

Burner Not Lighting

One or more heating elements did not heat up when turned on. Recommend qualified professional evaluate and repair.
photo_1773778200266.jpg
Moderate

Wall cracking

Vertical cracking was visible in a painted interior wall near a window or trim. Recommend patching and monitoring; if cracks reappear or widen, consult a qualified contractor to evaluate underlying mo...
Moderate

Door Doesn't Latch

Door doesn't latch properly. Recommend handyman repair latch and/or strike plate.
photo_1773777763703.jpg
Moderate

Frayed/deteriorated wiring sheathing observed in panel

Wires on the service entrance are damaged or frayed. Recommend contacting the electric utility company or a qualified electrician to evaluate and repair.
Moderate

Cover Plates Missing

One or more receptacles are missing a cover plate. This causes short and shock risk. Recommend installation of plates.
51C4130B-9938-472B-BD7B-71936D4A723B.heic
B2A2A14C-7EC2-4746-8BA8-B822261152DB.heic
Moderate

Missing Labels on Panel

At the time of inspection, panel was missing labeling. Recommend a qualified electrician or person identify and map out locations.
photo_1773779288658.jpg
Moderate

Sealant Applied

The back door has glass sealant applied to seal the glass to the door.
photo_1773777714498.jpg
photo_1773777720389.jpg
Moderate

Furnace should be cleaned and serviced annually

The furnace should be cleaned and serviced annually. Recommend a qualified HVAC contractor clean, service, and certify the heating equipment.
Moderate

Improper drain connection at sink P-trap

Improper connection observed at the sink drain. Flexible corrugated trap components and non-standard fittings are prone to debris buildup and may contribute to clogs or leaks. Recommend a qualified pl...
Moderate

Venting/flue installation appears non-standard

Venting and flue connections appear to be installed in a non-standard manner. Recommend a qualified plumber or HVAC contractor evaluate the venting and correct as necessary.
Minor

Water damaged ceiling

Water staining and paint bubbling were observed on the bedroom ceiling near a light fixture. Recommend identifying and correcting the source of moisture intrusion before repairing and repainting affec...
Minor

Flooring surface damage observed

Delamination and surface damage were observed on plank-style resilient flooring. Recommend a qualified flooring contractor evaluate and repair or replace affected planks.
Minor

Damaged or missing screen

Various window insect screens were observed to be torn or damaged. Recommend replacement of damaged screens to restore insect protection and proper function.
Minor

Exposed/loose conductors inside panel

Exposed wiring was observed in some areas of the panel. Recommend a qualified electrician route conductors in walls, conduit, or approved enclosures as needed.
Minor

Sink - Poor drainage

The sink had slow drainage observed during testing. Recommend a qualified plumber evaluate and repair as needed.
Minor

Sink Stopper Missing

No sink stopper was present or installed at the time of inspection. Recommend replacing the sink stopper.
photo_1773778711362.jpg