720 Willow Creek Court
Park City, UT 00000
Inspected September 10, 2026Prepared by Evergreen Home InspectionsOverview
18 items
Safety
No Handrail
Staircase had no handrails. This is a safety hazard. Recommend a qualified handyman install a handrail. All stairs with 4 or more risers should have a graspable handrail.

Major
Siding cracking
Siding showed cracking in one or more places. Recommend a qualified siding contractor evaluate and repair affected sections as needed.
Moderate
Burner Not Lighting
One or more heating elements did not heat up when turned on. Recommend qualified professional evaluate and repair.

Moderate
Wall cracking
Vertical cracking was visible in a painted interior wall near a window or trim. Recommend patching and monitoring; if cracks reappear or widen, consult a qualified contractor to evaluate underlying mo...
Moderate
Door Doesn't Latch
Door doesn't latch properly. Recommend handyman repair latch and/or strike plate.

Moderate
Frayed/deteriorated wiring sheathing observed in panel
Wires on the service entrance are damaged or frayed. Recommend contacting the electric utility company or a qualified electrician to evaluate and repair.
Moderate
Cover Plates Missing
One or more receptacles are missing a cover plate. This causes short and shock risk. Recommend installation of plates.


Moderate
Missing Labels on Panel
At the time of inspection, panel was missing labeling. Recommend a qualified electrician or person identify and map out locations.

Moderate
Sealant Applied
The back door has glass sealant applied to seal the glass to the door.


Moderate
Furnace should be cleaned and serviced annually
The furnace should be cleaned and serviced annually. Recommend a qualified HVAC contractor clean, service, and certify the heating equipment.
Moderate
Improper drain connection at sink P-trap
Improper connection observed at the sink drain. Flexible corrugated trap components and non-standard fittings are prone to debris buildup and may contribute to clogs or leaks. Recommend a qualified pl...
Moderate
Venting/flue installation appears non-standard
Venting and flue connections appear to be installed in a non-standard manner. Recommend a qualified plumber or HVAC contractor evaluate the venting and correct as necessary.
Minor
Water damaged ceiling
Water staining and paint bubbling were observed on the bedroom ceiling near a light fixture. Recommend identifying and correcting the source of moisture intrusion before repairing and repainting affec...
Minor
Flooring surface damage observed
Delamination and surface damage were observed on plank-style resilient flooring. Recommend a qualified flooring contractor evaluate and repair or replace affected planks.
Minor
Damaged or missing screen
Various window insect screens were observed to be torn or damaged. Recommend replacement of damaged screens to restore insect protection and proper function.
Minor
Exposed/loose conductors inside panel
Exposed wiring was observed in some areas of the panel. Recommend a qualified electrician route conductors in walls, conduit, or approved enclosures as needed.
Minor
Sink - Poor drainage
The sink had slow drainage observed during testing. Recommend a qualified plumber evaluate and repair as needed.
Minor
Sink Stopper Missing
No sink stopper was present or installed at the time of inspection. Recommend replacing the sink stopper.