1234 Sample Street

Anytown, OR 00000
Inspected on May 18, 2026
Prepared by Evergreen Home Inspections

Safety Items

1

No Handrail

Safety
Staircase had no handrails. This is a safety hazard. Recommend a qualified handyman install a handrail. All stairs with 4 or more risers should have a graspable handrail.
photo_1773777881937.jpg

For Consideration

17

Siding cracking

Major
Siding showed cracking in one or more places. Recommend a qualified siding contractor evaluate and repair affected sections as needed.

Burner Not Lighting

Moderate
One or more heating elements did not heat up when turned on. Recommend qualified professional evaluate and repair.
photo_1773778200266.jpg

Wall cracking

Moderate
Vertical cracking was visible in a painted interior wall near a window or trim. Recommend patching and monitoring; if cracks reappear or widen, consult a qualified contractor to evaluate underlying mo...

Door Doesn't Latch

Moderate
Door doesn't latch properly. Recommend handyman repair latch and/or strike plate.
photo_1773777763703.jpg

Frayed/deteriorated wiring sheathing observed in panel

Moderate
Wires on the service entrance are damaged or frayed. Recommend contacting the electric utility company or a qualified electrician to evaluate and repair.

Cover Plates Missing

Moderate
One or more receptacles are missing a cover plate. This causes short and shock risk. Recommend installation of plates.
51C4130B-9938-472B-BD7B-71936D4A723B.heic
B2A2A14C-7EC2-4746-8BA8-B822261152DB.heic

Missing Labels on Panel

Moderate
At the time of inspection, panel was missing labeling. Recommend a qualified electrician or person identify and map out locations.
photo_1773779288658.jpg

Sealant Applied

Moderate
The back door has glass sealant applied to seal the glass to the door.
photo_1773777714498.jpg
photo_1773777720389.jpg

Furnace should be cleaned and serviced annually

Moderate
The furnace should be cleaned and serviced annually. Recommend a qualified HVAC contractor clean, service, and certify the heating equipment.

Improper drain connection at sink P-trap

Moderate
Improper connection observed at the sink drain. Flexible corrugated trap components and non-standard fittings are prone to debris buildup and may contribute to clogs or leaks. Recommend a qualified pl...

Venting/flue installation appears non-standard

Moderate
Venting and flue connections appear to be installed in a non-standard manner. Recommend a qualified plumber or HVAC contractor evaluate the venting and correct as necessary.

Water damaged ceiling

Minor
Water staining and paint bubbling were observed on the bedroom ceiling near a light fixture. Recommend identifying and correcting the source of moisture intrusion before repairing and repainting affec...

Flooring surface damage observed

Minor
Delamination and surface damage were observed on plank-style resilient flooring. Recommend a qualified flooring contractor evaluate and repair or replace affected planks.

Damaged or missing screen

Minor
Various window insect screens were observed to be torn or damaged. Recommend replacement of damaged screens to restore insect protection and proper function.

Exposed/loose conductors inside panel

Minor
Exposed wiring was observed in some areas of the panel. Recommend a qualified electrician route conductors in walls, conduit, or approved enclosures as needed.

Sink - Poor drainage

Minor
The sink had slow drainage observed during testing. Recommend a qualified plumber evaluate and repair as needed.

Sink Stopper Missing

Minor
No sink stopper was present or installed at the time of inspection. Recommend replacing the sink stopper.
photo_1773778711362.jpg